Summary for Test 2016-10-26-4-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209217
DEA: 080F5404
EFIS: 0800000136
COOP: 081468
DIST-CO-RTE-PM08-RIV-91,15-0.0/13.04, 35.64/45.14
Award Date09/09/2013
Closeout Date09/20/2023
Work DescriptionSR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
QA Service Level1 (Verified on 08/07/2014)

Sample Information

Sample Taken Date10/26/2016 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing10/28/2016 Sample typeQuality Control
A brief description of the sample6X12 The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byARMANDO
Last name of sampler or witnessed bySALAZAR Title of samplerTE
Telephone number of samplerUnknown Laboratory sample identification888-SRL345
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHOLLIDAY
Transportation Laboratory (TL) NumberSRL 345 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier910 CIP Structure nameBR18 RIGHT DECK
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number645
The truck number from where the sample was collected645 The batch plant ticket number from where the sample was collected118054904
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 17 Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-10-26-4
DIME Test ID: 2016-10-26-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-11-03

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 11/02/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 134200 lb
Maximum load on cylinder 2: 135870 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 4715.4 psi
Compressive strength of cylinder 2: 4774.1 psi
Compressive strength (to nearest 10 psi): 4740 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/3/2016 ✔