Summary for Test 2022-09-21-67-1

Test performed: ASTM D36-14ε1

Project Information

Project IdentifiersProject ID: 213707
DEA: 081C38U4
EFIS: 0817000196
DIST-CO-RTE-PM08-RIV-10-6.7/R25.1
Award Date11/26/2019
Closeout Date11/01/2023
Work DescriptionRemove concrete pavement and base, and place HMA and JPCP
Location DescriptionROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
QA Service Level1 (Verified on 01/09/2020)

Sample Information

Sample Taken Date09/21/2022 Sample Unique Key67
Date that the sample was received by the laboratory/organization performing the testing09/29/2022 Sample typePer Request
A brief description of the sampleAsphalt Rubber Binder The quantity of what the sample constitutes1 Quart Can
From where was the sample collectedSupplier First name of sampler or witnessed byMartin Marietta QC
Last name of sampler or witnessed byMartin Marietta QC Title of sampler
Telephone number of sampler Laboratory sample identification0665-22
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta -Coachella
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2022-09-21-67
DIME Test ID: 2022-09-21-67-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2022-11-05

Test Results


ASTM Thermometer used?: C
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 10/10/2022
Softening Point Sample 1: 72 C
Softening Point Sample 2: 73 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/5/2022