Summary for Test 2022-10-18-1-4
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 88887 DEA: PC-Barrier-STOCK EFIS: PC-Barrier-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for precast barrier rail stock material. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/18/2022 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2022 |
| Sample type | Stock | A brief description of the sample | 1 1/4" Galvanized Heavy Hex Nuts |
| The quantity of what the sample constitutes | 2,250 pcs. | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 3109128014 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Blue Circle Corporation | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 5804750704 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | N/A | |
| Bolt Length(s) | Nut Specification | ASTM A193 | |
| Washer Specification | N/A | Finish | ASTM F2329/A153 Hot Dip |
| Diameter/Size | Bolt Mfg. Lot Number | ||
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2022-10-18-1
DIME Test ID: 2022-10-18-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2022-10-28
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 10/26/2022
UTM: 400kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 170868 | Nut Proof Load |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 10/28/2022 ✔