Summary for Test 2022-10-20-3-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 88887
DEA: PC-Barrier-STOCK
EFIS: PC-Barrier-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for precast barrier rail stock material.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/20/2022 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing10/20/2022 Sample typeStock
A brief description of the sample3/8" x 6" All Thread Rod The quantity of what the sample constitutes116
From where was the sample collectedFabricator First name of sampler or witnessed byEdward
Last name of sampler or witnessed byLeach Title of samplerQA
Telephone number of sampler7072903887 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUIS Lindon UT
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100011596322 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt Specificationn/a
Bolt Length(s) Nut Specificationn/a
Washer Specificationn/a FinishHDG
Diameter/Size3/8" x 6" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2022-10-20-3
DIME Test ID: 2022-10-20-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2022-10-28

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/26/2022
UTM: 400kip
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AUNC 3/8 0.077511075491429081272629863A449 Tensile

General comments (publicly viewable) (Max 1000 characters): A449 Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 10/28/2022 ✔