Summary for Test 2022-09-19-29-3
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-6.7/R25.1 |
Award Date | 11/26/2019 |
Closeout Date | 11/01/2023 |
Work Description | Remove concrete pavement and base, and place HMA and JPCP |
Location Description | ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON. |
QA Service Level | 1 (Verified on 01/09/2020) |
Sample Information
Sample Taken Date | 09/19/2022 | Sample Unique Key | 29 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/23/2022 |
Sample type | Verification | A brief description of the sample | Asphalt Rubber Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Martin Marietta QC | Last name of sampler or witnessed by | Martin Marietta QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0658-22 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Martin Marietta -Coachella | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-09-19-29
DIME Test ID: 2022-09-19-29-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2022-10-12
Test Results
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 10/12/2022
Temperature: 25 C
Final Dial reading (F1): 48 mm
Ball Penetration (P1): 0 mm
Final Dial reading (F2): 49 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F3): 48 mm
Ball Penetration (P3): 0 mm
Resilience 1: 52 %
Resilience 2: 51 %
Resilience 3: 52 %
Average Resilience: 52 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/12/2022 ✔