Summary for Test 2022-10-05-1-2

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 214993
DEA: 051F5004
EFIS: 0514000003
DIST-CO-RTE-PM05-SB-101,135-70.6/71.2;0.1
Award Date11/17/2020
Closeout Date01/11/2024
Work DescriptionCONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA.
Location DescriptionSANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION
QA Service Level1 (Verified on 09/03/2020)

Sample Information

Sample Taken Date10/05/2022 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/05/2022
Sample typeQuality Assurance A brief description of the sampleNative Soil
The quantity of what the sample constitutesGeo embankment fill From where was the sample collectedJob Site
First name of sampler or witnessed byIsaac Last name of sampler or witnessed byGleffe
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNative soil Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedOn site stockpile
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-10-05-1
DIME Test ID: 2022-10-05-1-2
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2022-10-10

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Daniel Gingras
Date of test: 10/10/2022
Minimum soil resistance of the lab measurement: 3200 Ohms
Soil sample temperature: 21.4 C
Soil box constant: 1
pH of soil: 7.33
Minimum soil resistance corrected to 15.5: 3672.00 Ohm-cm
Minimum soil resistivity at 15.5: 3672 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/10/2022