Summary for Test 2022-08-25-59-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215783
DEA: 033H3304
EFIS: 0317000325
DIST-CO-RTE-PM03-YOL,SAC-50-2.5/3.2,L0.0/18.3
Award Date08/20/2021
Closeout Date01/22/2024
Work DescriptionINSTALL CMS, FIBER OPTIC CABLE SYSTEMS AND CAMERA SYSTEMS.
Location DescriptionYOLO COUNTY AND SACRAMENTO COUNTY ON ROUTE 50 FROM JEFFERSON BOULEVARD TO 1.3 MILES EAST OF FOLSOM BOULEVARD
QA Service Level1 (Verified on 07/26/2021)

Sample Information

Sample Taken Date08/25/2022 Sample Unique Key59
Date that the sample was received by the laboratory/organization performing the testing08/25/2022 Sample typeQuality Control
A brief description of the sampleConcrete The quantity of what the sample constitutes100 Cy
From where was the sample collectedJob Site First name of sampler or witnessed byRaul
Last name of sampler or witnessed byAtilano Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1615453
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected30410746
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedfoundation for CCTV Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-08-25-59
DIME Test ID: 2022-08-25-59-5
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-09-29

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 09/22/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 134630 lb
Maximum load on cylinder 2: 133810 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4750 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/29/2022 ✔