Summary for Test 2022-08-23-9-6
Test performed: ASTM B499-09r21Project Information
| Project Identifiers | Project ID: 214590 DEA: 043G4744 EFIS: 0412000074 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN,MRN-580-6.9/7.8,0.0/2.5 |
| Award Date | 01/14/2021 |
| Closeout Date | 08/19/2024 |
| Work Description | CLEAN AND PAINT STRUCTURAL STEEL BRIDGE. |
| Location Description | CONTRA COSTA AND MARIN COUNTIES IN RICHMOND AND SAN RAFAEL FROM 0.8 MILE WEST OF TOLL PLAZA TO 0.1 MILE EAST OF MAIN STREET |
| QA Service Level | 1 (Verified on 02/18/2020) |
Sample Information
| Sample Taken Date | 08/23/2022 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/26/2022 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG bolts,nuts and washers |
| The quantity of what the sample constitutes | 47 assemblies | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
| Laboratory sample identification | Linked DIME Sample ID | B9-134-22 | |
| The fabricator/manufacturer/facility name | C&K Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-133-22 | Structure unique identifier | |
| Structure name | Richmond- San Rafael | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 464463AR |
|---|---|---|---|
| Heat Number(s) | bolt 100212503 nut 800013379 washer 201905 | Nut Mfg. Lot Number(s) | Nucor 464120C |
| Washer Mfg. Lot Number(s) | Prestige E0506 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2 1/4" | Nut Specification | ASTM A563 DH Hvy Hex |
| Washer Specification | ASTM F436 STR Round | Finish | HDG |
| Diameter/Size | 7/8 x 2 1/4" | Bolt Mfg. Lot Number | Nucor 464463A |
| Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2022-08-23-9
DIME Test ID: 2022-08-23-9-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2022-09-20
Test Results
Input Type: Calculated
Tester's full name: Ruben Macias
Date of test: 09/20/2022
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: E0506
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: P F436
Size: .875 in
Bolt Length: no data
Measurement Average: 3.87 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/20/2022 ✔