Summary for Test 2016-08-19-10-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 7427
DEA: 07215934
EFIS: 0700001833
DIST-CO-RTE-PM07-LA-5-2.4/4.0
Award Date08/14/2012
Closeout Date02/20/2020
Work DescriptionWiden and Realign Freeway and Construct Ped OC, OC and UC Structures.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 11/26/2012)

Sample Information

Sample Taken Date08/19/2016 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing08/25/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutesUnknown
From where was the sample collectedFabricator First name of sampler or witnessed byRussel
Last name of sampler or witnessed byLynch Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) NumberC970404 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65024565
Hoop Manufacturer Lot Number(s)4 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop4'-1.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerRKR Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-08-19-10
DIME Test ID: 2016-08-19-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-08-29

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/26/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
114#6/19mm0.444207095610Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/29/2016 ✔