Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-08-19-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7427
DEA: 07215934
EFIS: 0700001833
DIST-CO-RTE-PM07-LA-5-2.4/4.0
Award Date08/14/2012
Closeout Date02/20/2020
Work DescriptionWiden and Realign Freeway and Construct Ped OC, OC and UC Structures.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 11/26/2012)

Sample Information

Sample Taken Date08/19/2016 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutesUnknown From where was the sample collectedFabricator
First name of sampler or witnessed byRussel Last name of sampler or witnessed byLynch
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberC970404
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65024565
Hoop Manufacturer Lot Number(s)4 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop4'-1.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerRKR Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-08-19-10-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/2016Brian
Yes
08/29/2016Bar Broke; OK Necking
2016-08-19-10-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/2016Brian
Yes
08/29/2016Bar Broke; OK Necking
2016-08-19-10-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/2016Brian
Yes
08/29/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-08-19-10-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-19-10-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-19-10-3 CTM 670-December 2013 (Verified)