Summary for Test 2022-08-02-10-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 215221 DEA: 07332604 EFIS: 0716000287 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-R12.4/14.9 |
Award Date | 12/16/2020 |
Closeout Date | 11/25/2024 |
Work Description | REMOVE RAISED ISLAND, CONSTRUCT CONCRETE BARRIER AND INSTALL LIGHTING. |
Location Description | THE COUNTY AND CITY OF LOS ANGELES FROM 0.1 MILE EAST OF ARLINGTON AVENUE OVERCROSSING TO 0.7 MILE EAST OF ROUTE 10/110 SEPARATION |
QA Service Level | 1 (Verified on 03/19/2021) |
Sample Information
Sample Taken Date | 08/02/2022 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/03/2022 |
Sample type | Department Acceptance | A brief description of the sample | Class 3 Aggregate Base |
The quantity of what the sample constitutes | 17976 SF | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Michelangelo | Last name of sampler or witnessed by | Sese |
Title of sampler | TET | Telephone number of sampler | 310-345-6204 |
Laboratory sample identification | 22-2028 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Class 3 Aggregate Base |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Various locations | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-08-02-10
DIME Test ID: 2022-08-02-10-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-08-03
Test Results
Method Type:: Direct Read
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 08/02/2022
Gage No.: 63091
Test No.: no data
Nuclear By: Michelangelo Sese
Non-Bias Plan No.: 7
Depth: 9
Material No.: no data
Material Type: Class 3 Aggregate Base
Impact By: Michelangelo Sese
Standard Count Density: 1609 g/cc
Count or Density 1: 2.05 g/cc
Count or Density 2: 2.07 g/cc
Count or Density 3: 2.02 g/cc
Count or Density 4: 2 g/cc
Count or Density 5: 2.03 g/cc
Standard Count Moisture: 656 g/cc
Moisture Count 1: 0.11 g/cc
Moisture Count 2: 0.12 g/cc
Moisture Count 3: 0.12 g/cc
Moisture Count 4: 0.11 g/cc
Moisture Count 5: 0.12 g/cc
Sum of Count or Density: 10.17 g/cc
Average of Count or Density: 2.03 g/cc
Sum of Moisture Count: 0.58 g/cc
Average of Moisture Count: 0.12 g/cc
Calculated Percent Relative Compaction: 95.9 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters): WB Rte. 10
Location 2 @ Normandie Ave
Sta. 697+80 to Sta. 714+60
Test was verified on 8/3/2022 ✔