Summary for Test 2022-07-18-1-5

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214989
DEA: 050L7224
EFIS: 0515000098
DIST-CO-RTE-PM05-SLO-1-34.5
Award Date10/13/2021
Closeout Date11/25/2024
Work DescriptionREPLACE BRIDGE.
Location DescriptionSAN LUIS OBISPO COUNTY NEAR MORRO BAY AT OLD CREEK BRIDGE
QA Service Level1 (Verified on 09/03/2020)

Sample Information

Sample Taken Date07/18/2022 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing07/25/2022 Sample typeQuality Assurance
A brief description of the sampleWelded Hoop The quantity of what the sample constitutes985
From where was the sample collectedManufacturer First name of sampler or witnessed byBrian
Last name of sampler or witnessed byMurray Title of samplerQA Inspector
Telephone number of sampler213 435 4055 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL140-115-22
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)171022
Hoop Manufacturer Lot Number(s)10 and 13 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop2'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2022-07-18-1
DIME Test ID: 2022-07-18-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2022-07-26

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 07/26/2022
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12135/16mm0.3129072.4993782ok neckingspaine

General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 7/26/2022 ✔