Summary for Test 2022-06-16-40-2
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 215221 DEA: 07332604 EFIS: 0716000287 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-R12.4/14.9 |
| Award Date | 12/16/2020 |
| Closeout Date | 11/25/2024 |
| Work Description | REMOVE RAISED ISLAND, CONSTRUCT CONCRETE BARRIER AND INSTALL LIGHTING. |
| Location Description | THE COUNTY AND CITY OF LOS ANGELES FROM 0.1 MILE EAST OF ARLINGTON AVENUE OVERCROSSING TO 0.7 MILE EAST OF ROUTE 10/110 SEPARATION |
| QA Service Level | 1 (Verified on 03/19/2021) |
Sample Information
| Sample Taken Date | 06/16/2022 | Sample Unique Key | 40 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/16/2022 | Sample type | Department Acceptance |
| A brief description of the sample | Subgrade | The quantity of what the sample constitutes | 2000 yd2 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Rosauro |
| Last name of sampler or witnessed by | Nogoy | Title of sampler | TEC |
| Telephone number of sampler | 2137939321 | Laboratory sample identification | 22-1445 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | NA | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Subgrade | A detailed description of where the material sample was collected | From various locations at subgrade. |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-06-16-40
DIME Test ID: 2022-06-16-40-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2022-06-29
Test Results
Is oversize material: No
Input Type: Measured
Tester's full name: Rosauro Nogoy
Date of test: 06/16/2022
In-place wet density: 2.05
Highest adjust wet density: 2.15
% Moisture: 3.3 %
Optimum Moisture: 7.3 %
Relative compaction: 95
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/29/2022 ✔