Summary for Test 2022-04-28-17-4

Test performed: ASTM C185-15a

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/28/2022 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing04/28/2022 Sample typeAuthorization
A brief description of the samplePLC Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM225235
Linked DIME Sample ID The fabricator/manufacturer/facility nameDevil's Slide PLC Cement
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandLaFarge Holcim
MillDevils Slide Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2022-04-28-17
DIME Test ID: 2022-04-28-17-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Test Release Date: 2022-06-27

Test Results


Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 05/25/2022
Specific gravity: 3.143
Water Content: 242
The amount of flow (In percent): 89 %
Gross Weight of Sample: 1575.6 grams
Tare Weight of Sample: 725.3 grams
The amount of water used (In percent): 69.14 %
Net Weight of Sample: 850.3 grams
Theoretical Mass per Unit Volume: 2.26
Actual Mass per Unit Volume: 2.13
Air Content: 6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/27/2022 ✔