Summary for Test 2022-06-09-24-1
Test performed: CTM 521-June 2012Project Information
| Project Identifiers | Project ID: 212246 DEA: 053307A4 EFIS: 0514000027 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-46-49.7/54.6 |
| Award Date | 02/16/2022 |
| Closeout Date | 09/02/2025 |
| Work Description | Cholame Segment |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/30/2019) |
Sample Information
| Sample Taken Date | 06/09/2022 | Sample Unique Key | 24 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/09/2022 | Sample type | Quality Assurance |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | Headwalls |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Kyle |
| Last name of sampler or witnessed by | Engen | Title of sampler | TET |
| Telephone number of sampler | 8055409933 | Laboratory sample identification | 220512-1 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | San Benito | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 710RN2010 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Wheel Barrow from Chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-06-09-24
DIME Test ID: 2022-06-09-24-1
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-06-13
Test Results
Number of specimens: 2
Input Type: Calculated
Tester's full name: Kyle Engen
Date of test: 06/09/2022
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): Cone Shear
Break Description of Cylinder 2 (if not 'cone'): Cone Shear
Average Compressive Strength (to nearest 10): 4130 lb/in^2
Compressive Strength of Cylinder 1: 4120 lb/in^2
Compressive Strength of Cylinder 2: 4140 lb/in^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/13/2022 ✔