Summary for Test 2021-12-13-20-6

Test performed: ASTM C187-16

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/13/2021 Sample Unique Key20
Date that the sample was received by the laboratory/organization performing the testing12/13/2021 Sample typeAuthorization
A brief description of the sampleBlended cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM225214
Linked DIME Sample ID The fabricator/manufacturer/facility nameSRMG
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandSalt River Materials Group
MillClarkdale Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2021-12-13-20
DIME Test ID: 2021-12-13-20-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Test Release Date: 2022-05-23

Test Results


Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 01/13/2022
Mass of Water: 178 g
Mass of Dry Cement: 650 g
Water required for normal consistency: 27.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/23/2022 ✔