Summary for Test 2016-06-09-5-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
| Award Date | 11/29/2012 |
| Closeout Date | 07/31/2023 |
| Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
| Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
| Sample Taken Date | 06/09/2016 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/14/2016 | Sample type | Quality Control |
| A brief description of the sample | 6X12 | The quantity of what the sample constitutes | 6 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | HUNG |
| Last name of sampler or witnessed by | NGO | Title of sampler | ASR |
| Telephone number of sampler | Unknown | Laboratory sample identification | 889-9A |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | NATIONAL READY MIX |
| Transportation Laboratory (TL) Number | 160609A | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | RW 1605 FTG STEP 5 FROM STA 607 32 12 TO 608 04 12 | Structure name | Unknown |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | S62578 |
|---|---|---|---|
| The truck number from where the sample was collected | 2002 | The batch plant ticket number from where the sample was collected | 97340 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | SHUTE | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-06-09-5
DIME Test ID: 2016-06-09-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-06-16
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 06/16/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 62840 lb
Maximum load on cylinder 2: 65390 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 2237.1 psi
Compressive strength of cylinder 2: 2327.9 psi
Compressive strength (to nearest 10 psi): 2280 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/16/2016 ✔