Summary for Test 2016-05-25-4-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 209384 DEA: 04264094 EFIS: 0400000735 COOP: 042531 |
|---|---|
| DIST-CO-RTE-PM | 04-,SON-- |
| Award Date | 01/21/2016 |
| Closeout Date | 06/03/2020 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 06/03/2020) |
Sample Information
| Sample Taken Date | 05/25/2016 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/26/2016 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Harris Salinas | Transportation Laboratory (TL) Number | C740268 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B904916 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | SE16100880 |
| Hoop Manufacturer Lot Number(s) | H07 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 8 |
| Diameter of Hoop | 5'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Harris Salinas |
| Welding Company | Harris Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-05-25-4
DIME Test ID: 2016-05-25-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-06-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/01/2016
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | H07 | #8/25mm | 0.79 | 75400 | 95440 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/1/2016 ✔