Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-05-25-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209384
DEA: 04264094
EFIS: 0400000735
COOP: 042531
DIST-CO-RTE-PM04-,SON--
Award Date01/21/2016
Closeout Date06/03/2020
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/03/2020)

Sample Information

Sample Taken Date05/25/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/26/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Salinas Transportation Laboratory (TL) NumberC740268
Inspector Lot Number from the Transportation Laboratory (TL) FormB904916 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE16100880
Hoop Manufacturer Lot Number(s)H07 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop5'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerHarris Salinas
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-05-25-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/2016Brian
Yes
06/01/2016Bar Broke; OK Necking
2016-05-25-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/2016Brian
Yes
06/01/2016Bar Broke; OK Necking
2016-05-25-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/2016Brian
Yes
06/01/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-25-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-25-4-2 CTM 670-December 2013 (Verified)