Summary for Test 2022-01-21-15-9
Test performed: ASTM C191-13Project Information
| Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/21/2022 | Sample Unique Key | 15 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/21/2022 | Sample type | Proficiency |
| A brief description of the sample | Portland Cement | The quantity of what the sample constitutes | 1 sample |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | na |
| Last name of sampler or witnessed by | na | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM228224 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CCRL Portland 224 | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | CCRL |
|---|---|---|---|
| Mill | CCRL | Type of Cementitious Material | Type II Cement |
Test Details
DIME Sample ID: 2022-01-21-15
DIME Test ID: 2022-01-21-15-9
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2022-03-17
Test Results
Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 03/15/2022
Type of Water Used: Type IV grade reagent water
Initial time of setting: 125 min
Final time of setting: 270 min
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/17/2022 ✔