Summary for Test 2022-03-01-6-9
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 215257 DEA: 11056374 EFIS: 1117000087 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-11-0.6/2.7 |
| Award Date | 02/16/2021 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT INTERCHANGE, PLACE JPCP, HMA, AND INSTALL LIGHTING. |
| Location Description | SAN DIEGO COUNTY NEAR SAN DIEGO FROM 0.2 MILE WEST OF SANYO AVENUE UNDERCROSSING TO 1.2 MILE EAST OF ENRICO FERMI DRIVE OVERCROSSING |
| QA Service Level | 1 (Verified on 11/25/2020) |
Sample Information
| Sample Taken Date | 03/01/2022 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/01/2022 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA PSU |
| The quantity of what the sample constitutes | 3 bags, 12 boxes, 3 cans | From where was the sample collected | Source |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Walker |
| Title of sampler | Telephone number of sampler | 8582480978 | |
| Laboratory sample identification | 4136-PSU | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | CCA Lakeside | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0036 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | source | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-01-6
DIME Test ID: 2022-03-01-6-9
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2024-08-29
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 03/03/2022
Mass of measure: 189.6 grams
Bulk dry specific gravity: 2.616
Mass of sample and measure #1: 331.7 grams
Mass of sample and measure #2: 331.3 grams
Volume of cylinder: 100.0 mL
Mass of sample #1: 142.1 grams
Mass of sample #2: 141.7 grams
Uncompacted voids #1: 45.7 %
Uncompacted voids #2: 45.8 %
Average uncompacted voids: 45.8 %
General comments (publicly viewable) (Max 1000 characters): Pass
Test was verified on 8/29/2024 ✔