Summary for Test 2021-06-23-51-9
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 215367 DEA: 021J4904 EFIS: 0220000084 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-32-14.0/20.0 |
| Award Date | 02/02/2021 |
| Closeout Date | 04/11/2024 |
| Work Description | PLACE HOT MIX ASPHALT (TYPE A). |
| Location Description | TEHAMA COUNTY ABOUT 28 MILES EAST OF FOREST RANCH FROM 1.1 MILES EAST OF DEER CREEK BRIDGE NO. 08-0068 TO 0.4 MILE WEST OF SLATE CREEK BRIDGE NO. 08-0154 |
| QA Service Level | 1 (Verified on 12/24/2020) |
Sample Information
| Sample Taken Date | 06/23/2021 | Sample Unique Key | 51 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/24/2021 |
| Sample type | Verification | A brief description of the sample | Combined Untreated Virgin Aggregate for use in 3/8-inch Type A HMA |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Derek | Last name of sampler or witnessed by | Serna |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D78856F | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Sierra Cascade Aggregate and Asphalt Products | Transportation Laboratory (TL) Number | 896901 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-32-0002::Chester Pit 1 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Laboratory Batched from Sized Untreated Virgin Stockpile Samples | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-23-51
DIME Test ID: 2021-06-23-51-9
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2022-02-01
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 07/27/2021
Mass of measure: 190.2 grams
Bulk dry specific gravity: 2.457
Mass of sample and measure #1: 325.9 grams
Mass of sample and measure #2: 326.0 grams
Volume of cylinder: 100.0 mL
Mass of sample #1: 135.7 grams
Mass of sample #2: 135.8 grams
Uncompacted voids #1: 44.8 %
Uncompacted voids #2: 44.7 %
Average uncompacted voids: 44.8 %
General comments (publicly viewable) (Max 1000 characters): The fine bulk specific gravity (AASHTO T 84) was determined on unwashed material.
Test was verified on 2/1/2022 ✔