Summary for Test 2016-03-23-5-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 209217
DEA: 080F5404
EFIS: 0800000136
COOP: 081468
DIST-CO-RTE-PM08-RIV-91,15-0.0/13.04, 35.64/45.14
Award Date09/09/2013
Closeout Date09/20/2023
Work DescriptionSR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
QA Service Level1 (Verified on 08/07/2014)

Sample Information

Sample Taken Date03/23/2016 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing03/25/2016 Sample typeQuality Assurance
A brief description of the sampleCoupon Casting The quantity of what the sample constitutes1
From where was the sample collectedDistributor First name of sampler or witnessed byDebbie
Last name of sampler or witnessed byOzuna Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameManchester Metals
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)17C16
Part Number (s)68 27 212 Material SpecificationA536
Grades65-45-12 Metal Foundry Manufacturer (Mill)Manchester Metals
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2016-03-23-5
DIME Test ID: 2016-03-23-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-03-30

Test Results


Number of Samples: 1
Input Type: Calculated
Tester's full name: Brian
Date of test: 03/29/2016
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
117C160.4930.1909524569013010.4Brian

General comments (publicly viewable) (Max 1000 characters): Sample FAILS - Low Elongation
Test Graph

Test was verified on 3/30/2016 ✔