Summary for Test 2022-01-10-26-3
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 214993 DEA: 051F5004 EFIS: 0514000003 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101,135-70.6/71.2;0.1 |
| Award Date | 11/17/2020 |
| Closeout Date | 01/11/2024 |
| Work Description | CONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA. |
| Location Description | SANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION |
| QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
| Sample Taken Date | 01/10/2022 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/10/2022 |
| Sample type | Department Acceptance | A brief description of the sample | 3/4" Class 2 AB |
| The quantity of what the sample constitutes | 1 days placement | From where was the sample collected | Source |
| First name of sampler or witnessed by | Salvador | Last name of sampler or witnessed by | Lopez-Zamora |
| Title of sampler | ARET | Telephone number of sampler | 8057483854 |
| Laboratory sample identification | 334 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Calportland-Garey | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-42-0014 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Class 2 aggregate base | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | 300 LFT approach and departure center median. | |
| Where the material sample would have been placed if not sampled | center median | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-01-10-26
DIME Test ID: 2022-01-10-26-3
Testing Lab: CT D05 - Santa Maria Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-01-25
Test Results
Number of tests: 3
Input Type: Measured
Tester's full name: Salvador Lopez-Zamora
Date of test: 01/10/2022
Temperature correction: 0
Temperature of solution: 70
Clay reading (test 1): 6.8
Sand reading (test 1): 3.5
Clay reading (test 2): 7.4
Sand reading (test 2): 3.6
Clay reading (test 3): 7
Sand reading (test 3): 3.3
Sand equivalent (test 1): 52
Sand equivalent (test 2): 49
Sand equivalent (test 3): 48
Sand equivalent before temperature correction: 50
Sand equivalent after temperature correction: 50
General comments (publicly viewable) (Max 1000 characters): Sample complies.
Test was verified on 1/25/2022 ✔