Summary for Test 2021-12-21-1-1

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 215753
DEA: 050N72U4
EFIS: 0520000169
DIST-CO-RTE-PM05-SB-101-4.4/R7.7
Award Date06/05/2021
Closeout DateNot set
Work DescriptionPlease cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description101 freeway in Summerland, CA
QA Service Level1 (Verified on 05/06/2021)

Sample Information

Sample Taken Date12/21/2021 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing12/27/2021 Sample typePer Request
A brief description of the sample#8 Rebar with HRC 150 T Head The quantity of what the sample constitutes448 T-Heads
From where was the sample collectedFabricator First name of sampler or witnessed byMatthew
Last name of sampler or witnessed byTemple Title of samplerQuality Assurance Inspector
Telephone number of sampler9162439722 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHRC Fountain Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4114518 Head Manufacturer Lot Number(s)1, 3
Rebar Size#8 Headed Bar Model NameHRC 150 T Heads
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rebar
Head ManufacturerNucor Head FabricatorNucor
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2021-12-21-1
DIME Test ID: 2021-12-21-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-12-28

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/28/2021
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
110.797875499689ok neckingspaine

General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 12/28/2021