Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-12-21-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215753
DEA: 050N72U4
EFIS: 0520000169
DIST-CO-RTE-PM05-SB-101-4.4/R7.7
Award Date03/01/2021
Closeout DateNot set
Work DescriptionPlease cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description101 freeway in Summerland, CA
QA Service Level1 (Verified on 05/06/2021)

Sample Information

Sample Taken Date12/21/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/27/2021
Sample typePer Request A brief description of the sample#8 Rebar with HRC 150 T Head
The quantity of what the sample constitutes448 T-Heads From where was the sample collectedFabricator
First name of sampler or witnessed byMatthew Last name of sampler or witnessed byTemple
Title of samplerQuality Assurance Inspector Telephone number of sampler9162439722
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Fountain Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4114518 Head Manufacturer Lot Number(s)1, 3
Rebar Size#8 Headed Bar Model NameHRC 150 T Heads
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rebar
Head ManufacturerNucor Head FabricatorNucor
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-12-21-1-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2021spaine
Yes
12/28/2021ok necking
2021-12-21-1-2ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2021spaine
Yes
12/28/2021ok necking
2021-12-21-1-3ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2021spaine
Yes
12/28/2021ok necking
2021-12-21-1-4ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2021spaine
Yes
12/28/2021ok necking
2021-12-21-1-5ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2021spaine
Yes
12/28/2021ok necking
2021-12-21-1-6ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2021spaine
Yes
12/28/2021ok necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-12-21-1-1 ASTM A970-18 (Verified)
DIME Test ID: 2021-12-21-1-2 ASTM A970-18 (Verified)
DIME Test ID: 2021-12-21-1-3 ASTM A970-18 (Verified)
DIME Test ID: 2021-12-21-1-4 ASTM A970-18 (Verified)
DIME Test ID: 2021-12-21-1-5 ASTM A970-18 (Verified)
DIME Test ID: 2021-12-21-1-6 ASTM A970-18 (Verified)