Summary for Test 2021-11-20-2-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
| Award Date | 06/06/2018 |
| Closeout Date | Not set |
| Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
| Location Description | LA/SBD County Line to PM 13.2 near I-15 |
| QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
| Sample Taken Date | 11/20/2021 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/20/2021 |
| Sample type | Quality Assurance | A brief description of the sample | Soil |
| The quantity of what the sample constitutes | 18000 sqf | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Julius | Last name of sampler or witnessed by | E |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | 11202021 TEST 01 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | AT THE JOB SITE | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2021-11-20-2
DIME Test ID: 2021-11-20-2-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2021-12-10
Test Results
Method Type:: Direct Read
Number of Tests:: 1
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Julius E
Date of test: 11/20/2021
Gage No.: 36647
Test No.: 1
Nuclear By: JULIUS E
Non-Bias Plan No.: 7
Depth: 6
Material No.: NATIVE
Material Type: SUBGRADE
Impact By: JULIUS E
Standard Count Density: 1972 g/cc
Count or Density 1: 1988 g/cc
Standard Count Moisture: 671 g/cc
Moisture Count 1: 88 g/cc
Sum of Count or Density: 1988 g/cc
Average of Count or Density: 1988 g/cc
Sum of Moisture Count: 88 g/cc
Average of Moisture Count: 88 g/cc
Calculated Percent Relative Compaction: 94.6 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/10/2021 ✔