Summary for Test 2021-11-13-8-4

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date11/13/2021 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/16/2021
Sample typePer Request A brief description of the samplePG Asphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byCesar Last name of sampler or witnessed byGomez
Title of sampler Telephone number of sampler
Laboratory sample identification0637-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-13-8
DIME Test ID: 2021-11-13-8-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-11-19

Test Results


Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Babak Rezaei
Date of test: 11/17/2021
Any material loss from containers during heating process/testing?: Yes
Mass of empty container #1: 169.378 grams
Mass of empty container #2: 166.191 grams
Mass of container #1 before test (m1i): 204.337 grams
Mass of container #2 before test (m2i): 201.165 grams
Mass of container #1 after test (m1f): 204.233 grams
Mass of container #2 after test (m2f): 201.069 grams
Average mass change: -0.286 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/19/2021