Summary for Test 2021-10-20-18-9
Test performed: ASTM C430-8Project Information
Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/20/2021 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2021 |
Sample type | Authorization | A brief description of the sample | PLC Blended Cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM212108 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Lafarge Exshaw | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | LaFarge North America |
---|---|---|---|
Mill | Exshaw | Type of Cementitious Material | Blended Cement |
Test Details
DIME Sample ID: 2021-10-20-18
DIME Test ID: 2021-10-20-18-9
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Test Release Date: 2021-11-22
Test Results
Type of Material: Hydraulic Cement
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 11/03/2021
Residue from the sample retained on the No. 325 sieve (Rs): 0.0012 grams
Sieve correction factor (C): 192.5
Corrected residue, % (Rc): 0.4 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325): 99.6 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/22/2021 ✔