Summary for Test 2021-10-20-7-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
Award Date | 12/03/2019 |
Closeout Date | 09/28/2022 |
Work Description | San Mateo US 101 Express Lanes North |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 10/20/2021 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/28/2021 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" A325 Bolt Assy |
The quantity of what the sample constitutes | 1 lot of 46 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
Title of sampler | QAI | Telephone number of sampler | 5624806984 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-047-21 | Structure unique identifier | |
Structure name | Toll Reader Gantry |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 411546BR |
---|---|---|---|
Heat Number(s) | 100790240 | Nut Mfg. Lot Number(s) | 430539A |
Washer Mfg. Lot Number(s) | D8407 | Bolt Specification | ASTM F3125, Grade A325 |
Bolt Length(s) | 2-1/2" | Nut Specification | F563, Gr. DH |
Washer Specification | F436 | Finish | MG |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 411546A |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2021-10-20-7
DIME Test ID: 2021-10-20-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-11-08
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 11/05/2021
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | 430539A | 72295 | Nut Proof | bewing |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 11/8/2021 ✔