Summary for Test 2021-10-20-5-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
| Award Date | 12/03/2019 |
| Closeout Date | 09/28/2022 |
| Work Description | San Mateo US 101 Express Lanes North |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 10/20/2021 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/28/2021 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" A325 Bolt Assy |
| The quantity of what the sample constitutes | 1 lot of 30 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
| Title of sampler | QAI | Telephone number of sampler | 5624806984 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-047-21 | Structure unique identifier | |
| Structure name | Toll Reader Gantry | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 427929BR |
|---|---|---|---|
| Heat Number(s) | 100898066 | Nut Mfg. Lot Number(s) | 453202A |
| Washer Mfg. Lot Number(s) | D9288 | Bolt Specification | ASTM F3125, Grade A325 |
| Bolt Length(s) | 2-1/2" | Nut Specification | F563, Gr. DH |
| Washer Specification | F436 | Finish | MG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 427929B |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2021-10-20-5
DIME Test ID: 2021-10-20-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-11-08
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 11/05/2021
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 427929B | 0.7500 | 48003 | 213.53 | 10.00 | A325 Bolt | bewing |
General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 11/8/2021 ✔