Summary for Test 2021-10-20-1-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214601
DEA: 041J5694
EFIS: 0419000313
DIST-CO-RTE-PM04-SM-101-0.0/21.8
Award Date12/03/2019
Closeout Date09/28/2022
Work DescriptionSan Mateo US 101 Express Lanes North
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date10/20/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/28/2021
Sample typeQuality Assurance A brief description of the sample1/2" A325 Bolt Assy
The quantity of what the sample constitutes97 From where was the sample collectedFabricator
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler5624806984
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-047-21 Structure unique identifier
Structure nameToll Reader Gantry

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)5/24/21A
Heat Number(s)NF12101250 Nut Mfg. Lot Number(s)449261A
Washer Mfg. Lot Number(s)D7925 Bolt SpecificationASTM F3125, Grade A325
Bolt Length(s)2-1/2" Nut SpecificationF563, Gr. DH
Washer SpecificationF436 FinishMG
Diameter/Size1/2" Bolt Mfg. Lot Number308810A
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2021-10-20-1
DIME Test ID: 2021-10-20-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-11-08

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/28/2021
UTM: 400kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1133883-580446950439632A194fsaylor

General comments (publicly viewable) (Max 1000 characters): A194
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 11/8/2021