Summary for Test 2021-09-01-13-5

Test performed: ASTM C185-15a

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/01/2021 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing09/01/2021 Sample typeAuthorization
A brief description of the samplePLC Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM212105
Linked DIME Sample ID The fabricator/manufacturer/facility nameLehigh Hanson
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandLehigh
MillRedding Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2021-09-01-13
DIME Test ID: 2021-09-01-13-5
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Test Release Date: 2021-11-15

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 10/11/2021
Specific gravity: 3.126
Water Content: 240
The amount of flow (In percent): 89 %
Gross Weight of Sample: 1563.6 grams
Tare Weight of Sample: 725.3 grams
The amount of water used (In percent): 68.57 %
Net Weight of Sample: 838.3 grams
Theoretical Mass per Unit Volume: 2.26
Actual Mass per Unit Volume: 2.10
Air Content: 7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2021 ✔