Summary for Test 2021-09-09-43-3
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
| Award Date | 12/03/2019 |
| Closeout Date | 09/28/2022 |
| Work Description | San Mateo US 101 Express Lanes North |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 09/09/2021 | Sample Unique Key | 43 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/14/2021 |
| Sample type | Verification | A brief description of the sample | 16 Mohes of RHMA-G |
| The quantity of what the sample constitutes | 16 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Cruz |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Hanson Sunol | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2021-09-09-43
DIME Test ID: 2021-09-09-43-3
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-10-14
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Randy Cortez
Date of test: 09/30/2021
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Treated | ||||||
109 psi | 151 psi | |||||
0.72 | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/14/2021 ✔