Summary for Test 2021-09-27-1-3

Test performed: ASTM C109-16a

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/27/2021 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/27/2021 Sample typeAuthorization
A brief description of the samplePLC Blended Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM212103
Linked DIME Sample ID The fabricator/manufacturer/facility nameCalPortland Mojave
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandCalPortland
MillMojave Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2021-09-27-1
DIME Test ID: 2021-09-27-1-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2021-11-15

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 10/04/2021
Age of specimen: 7 days
The amount of flow : 113 %
The amount of water used : 50.0 %
Compressive strength of 1st specimen : 4578 psi
Compressive strength of 2nd specimen: 5123 psi
Compressive strength of 3rd specimen : 4754 psi
Average Compressive strength (to nearest 10 psi): 4670 psi
General comments (publicly viewable) (Max 1000 characters): 7 day test -- Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109

Test was verified on 11/15/2021 ✔