Summary for Test 2021-09-17-10-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214099
DEA: 024F5904
EFIS: 0213000010
DIST-CO-RTE-PM02-TEH-5-R25.4
Award Date07/08/2020
Closeout Date08/14/2023
Work DescriptionBRIDGE SEISMIC RETROFIT AND SCOUR REPAIR.
Location DescriptionTEHAMA COUNTY IN RED BLUFF AT SACRAMENTO RIVER BRIDGE
QA Service Level1 (Verified on 05/07/2019)

Sample Information

Sample Taken Date09/17/2021 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing09/21/2021 Sample typeQuality Assurance
A brief description of the sample7/8 " dia A325 HDG Fastener assemblies The quantity of what the sample constitutes77 ea
From where was the sample collectedFabricator First name of sampler or witnessed byGreg
Last name of sampler or witnessed byThompson Title of samplerAssociate Steel Inspector
Telephone number of sampler510-376-7155 Laboratory sample identification
Linked DIME Sample ID2021-09-17-9 The fabricator/manufacturer/facility nameC K Johnson
Transportation Laboratory (TL) NumberC658229 Inspector Lot Number from the Transportation Laboratory (TL) FormB9-062-21
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)L748T1R
Heat Number(s)Bolt- 10671170 Nut- 800008882 Washer- 102021060 Nut Mfg. Lot Number(s)Nucor- 453592A
Washer Mfg. Lot Number(s)Technical Stamping- D9779 Bolt SpecificationF3125- A325-1
Bolt Length(s)2 1/4" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size7/8 " x 2 1/4" Bolt Mfg. Lot NumberFontana- L748T1
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2021-09-17-10
DIME Test ID: 2021-09-17-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-09-28

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 09/23/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A453592A72373Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/28/2021 ✔