Summary for Test 2021-08-04-40-3
Test performed: ASTM D5329-16Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/04/2021 | Sample Unique Key | 40 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/07/2021 | Sample type | Verification |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1 Quart Can |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | RMA Group |
| Last name of sampler or witnessed by | RMA Group | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0520-21 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AAA-Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-04-40
DIME Test ID: 2021-08-04-40-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-09-10
Test Results
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 09/10/2021
Temperature: 25 C
Ball Penetration (P1): 1 mm
Final Dial reading (F1): 75 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F2): 72 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 69 mm
Resilience 1: 26 %
Resilience 2: 28 %
Resilience 3: 31 %
Average Resilience: 28 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/10/2021 ✔