Summary for Test 2021-08-18-26-3

Test performed: ASTM D2369-Jul10

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Sample Information

Sample Taken Date08/18/2021 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing08/18/2021 Sample typeQuality Control
A brief description of the sample1 gallon can The quantity of what the sample constitutes80 drums
From where was the sample collectedSource First name of sampler or witnessed byDaniel
Last name of sampler or witnessed byTikusis Title of samplerTechnical Director
Telephone number of sampler707-330-9227 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameKwik Bond Polymers and Polynt
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1352897
Batch Number1352897 Mix number1352897

Test Details

DIME Sample ID: 2021-08-18-26
DIME Test ID: 2021-08-18-26-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Test Release Date: 2021-08-26

Test Results


Input Type: Calculated
Tester's full name: Daniel Tikusis
Date of test: 08/13/2021
Mean of two volatile content determination: 46.46
General comments (publicly viewable) (Max 1000 characters): Accepted based on supplier's results.

Test was verified on 8/26/2021 ✔