Sample Record

Owner Labs

  • Kwik Bond Polymers
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2021-08-18-26

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Sample Information

Sample Taken Date08/18/2021 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/18/2021
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes80 drums From where was the sample collectedSource
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byTikusis
Title of samplerTechnical Director Telephone number of sampler707-330-9227
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers and Polynt Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypePolyester Mfg. Lot Number(s)1352897
Batch number1352897 Mix number1352897

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-08-18-26-1ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related ProductsDaniel Tikusis, CT HQ - Sacramento Concrete Testing Laboratory08/13/2021Phillip Montes
Yes
08/26/2021Accepted based on supplier's results.
2021-08-18-26-2ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational ViscometerDaniel Tikusis, CT HQ - Sacramento Concrete Testing Laboratory08/13/2021Phillip Montes
Yes
08/26/2021Accepted based on supplier's results.
2021-08-18-26-3ASTM D2369-Jul10: Standard Test Method for Volatile Content of CoatingsDaniel Tikusis, CT HQ - Sacramento Concrete Testing Laboratory08/13/2021Phillip Montes
Yes
08/26/2021Accepted based on supplier's results.
2021-08-18-26-4ASTM D638-Dec14: Standard Test Method for Tensile Properties of PlasticsPhillip Montes, CT HQ - Sacramento Concrete Testing Laboratory08/20/2021Phillip Montes
Yes
08/26/2021Accepted based on supplier's results.
2021-08-18-26-5CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and StructuresDaniel Tikusis, CT HQ - Sacramento Concrete Testing Laboratory08/24/2021Phillip Montes
Yes
08/26/2021Accepted based on supplier's results.
2021-08-18-26-6SCAQMD 309-91-Feb93: Determination of Static Volatile EmissionsDaniel Tikusis, CT HQ - Sacramento Concrete Testing Laboratory08/18/2021Phillip Montes
Yes
08/26/2021Accepted based on supplier's results.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-18-26-1 ASTM D1475-Nov13 (Verified)
DIME Test ID: 2021-08-18-26-2 ASTM D2196-Feb15 (Verified)
DIME Test ID: 2021-08-18-26-3 ASTM D2369-Jul10 (Verified)
DIME Test ID: 2021-08-18-26-4 ASTM D638-Dec14 (Verified)
DIME Test ID: 2021-08-18-26-5 CTM 551-August 2012 (Verified)
DIME Test ID: 2021-08-18-26-6 SCAQMD 309-91-Feb93 (Verified)