Summary for Test 2015-09-03-3-3

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 209217
DEA: 080F5404
EFIS: 0800000136
COOP: 081468
DIST-CO-RTE-PM08-RIV-91,15-0.0/13.04, 35.64/45.14
Award Date09/09/2013
Closeout Date09/20/2023
Work DescriptionSR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
QA Service Level1 (Verified on 08/07/2014)

Sample Information

Sample Taken Date09/03/2015 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing09/04/2015 Sample typeQuality Control
A brief description of the sample6x12 The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byJUANCHO
Last name of sampler or witnessed bySEVILLA Title of samplerCONSULT TECH
Telephone number of samplerUnknown Laboratory sample identification888-SRL78
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameNP
Transportation Laboratory (TL) NumberSRL 78 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier91 CIP Structure nameBR 17 STEM AND SOFFIT
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number5640
The truck number from where the sample was collected262 The batch plant ticket number from where the sample was collected118032345
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 17 Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-09-03-3
DIME Test ID: 2015-09-03-3-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-10-01

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 10/01/2015
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 158470 lb
Maximum load on cylinder 2: 161160 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 5641.5 psi
Compressive strength of cylinder 2: 5737.3 psi
Compressive strength (to nearest 10 psi): 5690 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/1/2015 ✔