Summary for Test 2021-08-05-13-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date08/05/2021 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing08/09/2021 Sample typeVerification
A brief description of the sampleJMF 3/4" HMA-A R10, 0.5% LAS The quantity of what the sample constitutes10 Bags of Aggregate, 2 Bags of RAP
From where was the sample collectedManufacturer First name of sampler or witnessed byThomas
Last name of sampler or witnessed byShivers Title of sampler
Telephone number of sampler Laboratory sample identification0449A-21
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035::FISH CANYON QUARRY
The fabricator's/manufacturer's product name for the sample3/4 HMA-A R10 The fabricator/manufacturer designation for the sample
The plant number220805 SVA VLO A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-05-13
DIME Test ID: 2021-08-05-13-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-08-31

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Edmond Jabbour
Date of test: 08/23/2021
Sieve SizeCumulative Percent Passing
100 %
100 %
100 %
100 %
100 %
99 %
84 %
68 %
46 %
38 %
23 %
13 %
7 %
4 %
2.5 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 8/31/2021