Summary for Test 2021-08-14-3-4
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 215109 DEA: 081C8504 EFIS: 0813000047 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-0.0/5.8 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | ROADWAY EXCAVATION, HOT MIX ASPHALT, AND STRUCTURAL SHOTCRETE WALLS. |
Location Description | RIVERSIDE COUNTY NEAR LAKE ELSINORE FROM ORANGE COUNTY LINE TO MONTE VISTA STREET |
QA Service Level | 1 (Verified on 02/24/2021) |
Sample Information
Sample Taken Date | 08/14/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/17/2021 |
Sample type | Verification | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Eric | Last name of sampler or witnessed by | sequoia |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0476-21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CCA-Lake Elsinore | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-14-3
DIME Test ID: 2021-08-14-3-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-27
Test Results
Phase: Original binder
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 08/19/2021
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 64.7 degree
Dynamic Shear, G*/sin(δ): 2.52 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/27/2021 ✔