Summary for Test 2021-08-10-1-5
Test performed: ASTM A884-13Project Information
Project Identifiers | Project ID: 215109 DEA: 081C8504 EFIS: 0813000047 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-0.0/5.8 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | ROADWAY EXCAVATION, HOT MIX ASPHALT, AND STRUCTURAL SHOTCRETE WALLS. |
Location Description | RIVERSIDE COUNTY NEAR LAKE ELSINORE FROM ORANGE COUNTY LINE TO MONTE VISTA STREET |
QA Service Level | 1 (Verified on 02/24/2021) |
Sample Information
Sample Taken Date | 08/10/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/13/2021 |
Sample type | Quality Assurance | A brief description of the sample | 150 ksi All Thread Bar |
The quantity of what the sample constitutes | Heat 100100654 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Weeks |
Title of sampler | ASI | Telephone number of sampler | 310 883 8369 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Williams Form Engineering San Diego | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-038-21 | Structure unique identifier | |
Structure name | RW388R, RW466R, RW472R, RW474R, RW536R |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
Threaded Bar Type | Plain | Rebar Size | #11 |
Nut Specification for Threaded Bar | A29 | System Manufacturer | Williams Form Engineering |
Epoxy Coating Color | Purple | Threaded Bar Application | Soil Nail |
Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100100654 |
Nut Heat Number(s) | 75081194 | Bar Lot Number | NA |
Nut Lot Number | Heat Code 36E5D | Coupler Heat Number(s) | NA |
Coupler Grade | NA |
Test Details
DIME Sample ID: 2021-08-10-1
DIME Test ID: 2021-08-10-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Test Release Date: 2021-08-17
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 08/16/2021
Total Number of Holiday: 0
Total Length: 14
Holidays Per Linear Foot of Bar: 0
Holiday Test Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2021 ✔