Summary for Test 2021-08-09-15-4
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 214402 DEA: 010E7704 EFIS: 0115000009 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-101-R17.9/87.8 |
| Award Date | 01/21/2020 |
| Closeout Date | 07/21/2023 |
| Work Description | STRENGTHEN 2 BRIDGES. |
| Location Description | HUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD |
| QA Service Level | 1 (Verified on 09/16/2019) |
Sample Information
| Sample Taken Date | 08/09/2021 | Sample Unique Key | 15 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2021 |
| Sample type | Quality Assurance | A brief description of the sample | #7 Barlock D250L Couplers |
| The quantity of what the sample constitutes | 72 Couplers | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Xavier | Last name of sampler or witnessed by | Carrillo |
| Title of sampler | ASR | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Camblin Steel | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC and Cascade |
| Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | |
| Rebar Size | #7 | Coupler Model | Barlock D250L |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | A200340 182336 | Rebar Heat Number(s) | 4093000 157521 |
| Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-08-09-15
DIME Test ID: 2021-08-09-15-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-08-12
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/12/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 4 | No. 7/22mm | 1 | 0 | 0.6 | 59139 | 98565 | Service Splice | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 8/12/2021 ✔