Summary for Test 2021-08-06-15-5
Test performed: ASTM A416-15Project Information
| Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
| Award Date | 06/06/2018 |
| Closeout Date | Not set |
| Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
| Location Description | LA/SBD County Line to PM 13.2 near I-15 |
| QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
| Sample Taken Date | 08/06/2021 | Sample Unique Key | 15 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/10/2021 |
| Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
| The quantity of what the sample constitutes | 42 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | Number of Coils | ||
| Group Number | 10975 | Strand Diameter | .6 in |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0573821, S0583421, S0574321-2, S0574221, S0592021, S0574421-2 | Mfg. Lot Number(s) | NA |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2021-08-06-15
DIME Test ID: 2021-08-06-15-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-08-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 08/11/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0574321-2 | S335827-2 | 0.216 | 59065 | 54333.0 | 28.5 | 1.9 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 8/11/2021 ✔