Summary for Test 2021-06-25-19-5

Test performed: AASHTO T313-19

Project Information

Project IdentifiersProject ID: 215624
DEA: 020J4004
EFIS: 0219000115
DIST-CO-RTE-PM02-SIS-161-17.5/18.5
Award Date05/11/2021
Closeout Date09/27/2021
Work DescriptionFULL DEPTH RECLAMATION - CEMENT AND PLACE HMA.
Location DescriptionSISKIYOU COUNTY NEAR TULELAKE FROM 0.3 MILE EAST OF MALONE ROAD TO 1.2 MILES EAST OF HILL ROAD
QA Service Level1 (Verified on 04/19/2021)

Sample Information

Sample Taken Date06/25/2021 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing07/13/2021 Sample typeDepartment Acceptance
A brief description of the samplePG58-34M The quantity of what the sample constitutes1 OF 2 CANS
From where was the sample collectedSource First name of sampler or witnessed byRANDY
Last name of sampler or witnessed byBIBBINS Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAlbina - Klamath Falls, OR
Transportation Laboratory (TL) Number990940 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt - Klamath Falls Plant - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2021-06-25-19
DIME Test ID: 2021-06-25-19-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2021-07-23

Test Results


Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 07/21/2021
Minimum test bath temperature at 240 s: -24.0 C
Maximum test bath temperature at 240 s: -24.0 C
Time of test load application: no data
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): 0
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 1007.0 mN
Beam deflection 60.0 s: 0.282 µm
Measured Stiffness Modulus 60.0 s: 288.000 mPa
Estimated Stiffness Modulus 60.0 s: 288.000 mPa
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.274
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/23/2021 ✔