Summary for Test 2021-04-27-28-3

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 214511
DEA: 010E0004
EFIS: 0113000091
DIST-CO-RTE-PM01-HUM-101-84.4/84.8
Award Date01/29/2020
Closeout Date11/22/2023
Work DescriptionBRIDGE RAIL REPLACEMENT.
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE
QA Service Level1 (Verified on 11/13/2019)

Sample Information

Sample Taken Date04/27/2021 Sample Unique Key28
Date that the sample was received by the laboratory/organization performing the testing05/25/2021 Sample typeDispute Resolution
A brief description of the sample1/2" HMA NO RAP The quantity of what the sample constitutes_
From where was the sample collectedManufacturer First name of sampler or witnessed by_
Last name of sampler or witnessed by_ Title of sampler
Telephone number of sampler Laboratory sample identification21-JMF-0102
Linked DIME Sample ID The fabricator/manufacturer/facility nameMercer Fraser - Fortuna
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-12-0002
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-27-28
DIME Test ID: 2021-04-27-28-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2021-06-07

Test Results


Input Type: Measured
Tester's full name: Jay Horton
Date of test: 06/02/2021
Grading designation: C
Mass of sample (before test): 5002 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4724 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3777 grams
Percent loss after 100 revolutions: 6 %
Percent loss after 500 revolutions: 24 %
General comments (publicly viewable) (Max 1000 characters): At 100 rev and 500 rev

Test was verified on 6/7/2021 ✔