Summary for Test 2021-04-01-32-1

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 215062
DEA: 030F2904
EFIS: 0314000101
DIST-CO-RTE-PM03-BUT-99-14.9/15.7
Award Date09/24/2020
Closeout Date03/02/2022
Work DescriptionCONSTRUCT BRIDGE AND ROADWAY; & REMOVE BRIDGE.
Location DescriptionBUTTE COUNTY ABOUT 10 MILES NORTH OF GRIDLEY FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF NELSON AVENUE
QA Service Level1 (Verified on 07/20/2020)

Sample Information

Sample Taken Date04/01/2021 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing04/01/2021 Sample typeVerification
A brief description of the sample3/4" (Nominal Size) Untreated Virgin Aggregate The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byTeichert Personnel (SAMPLER)
Last name of sampler or witnessed by Brad McKeehan (WITNESS) Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample IDJMF21-020B The fabricator/manufacturer/facility nameTeichert - Hallwood Plant
Transportation Laboratory (TL) NumberC706327 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-58-0006::HALLWOOD PLANT
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-01-32
DIME Test ID: 2021-04-01-32-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2021-06-02

Test Results


Method: 2 - Individual Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 04/19/2021
Weighted average percentage of fractured, coarse, 2 faced particles: 92 %
Weighted average percentage of fractured, coarse, 1 faced particles: 96 %
Percentage of fractured, fine, 1 faced particles tested: 99 %
General comments (publicly viewable) (Max 1000 characters): JMF21-020B.

Test was verified on 6/2/2021 ✔