Summary for Test 2021-06-01-3-2
Test performed: ASTM C109-16aProject Information
| Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/01/2021 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/01/2021 | Sample type | Proficiency |
| A brief description of the sample | CCRL pozzolan | The quantity of what the sample constitutes | 1 box |
| From where was the sample collected | Source | First name of sampler or witnessed by | na |
| Last name of sampler or witnessed by | na | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM218070 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CCRL | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | CCRL |
|---|---|---|---|
| Mill | CCRL Pozzolan | Type of Cementitious Material | Class F or N Flyash |
Test Details
DIME Sample ID: 2021-06-01-3
DIME Test ID: 2021-06-01-3-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2022-03-21
Test Results
Will control cubes be used per ASTM C311?: yes
Input Type: Measured
Tester's full name: AV
Date of test: 06/01/2021
Age of specimen: 0 days
The amount of flow : 116.00 %
The amount of water used : 47.0 %
Compressive strength of 1st specimen : 4506 psi
Compressive strength of 2nd specimen: 4674 psi
Compressive strength of 3rd specimen : 4414 psi
Average Compressive strength (to nearest 10 psi): 4530 psi
Average Compressive strength (to nearest 10 psi) control group: 0 psi
Strength Activity Index of Portland Cement per ASTM C109: no data
General comments (publicly viewable) (Max 1000 characters): 7 day test
Test Graph
Test was verified on 3/21/2022 ✔