Summary for Test 2021-05-13-7-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 214355 DEA: 120K0214 EFIS: 1214000096 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-12.4/14.5 |
| Award Date | 12/20/2019 |
| Closeout Date | 10/02/2025 |
| Work Description | South County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY |
| Location Description | ORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING |
| QA Service Level | 1 (Verified on 10/31/2019) |
Sample Information
| Sample Taken Date | 05/13/2021 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2021 |
| Sample type | Quality Assurance | A brief description of the sample | LENTON FORM SAVER (Sleeve-Tapered Thread) |
| The quantity of what the sample constitutes | (4) LENTON FORM SAVER (Sleeve-Tapered Thread) | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Marin |
| Title of sampler | AMR | Telephone number of sampler | 9515000685 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Coreslab Structures L A Inc | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L133-058-21 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC Steel Arizona |
| Coupler Manufacturer | Erico nVent | Intermediate Assembler or Fabricator | Coreslab Structures L A Inc |
| Rebar Size | #8 | Coupler Model | ST-17-05 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | NA | |
| Coupler Component Heat/Lot Number(s) | L9814 | Rebar Heat Number(s) | 4102817 |
| Rebar Size 2 | 8 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-05-13-7
DIME Test ID: 2021-05-13-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-05-18
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/14/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | No. 8/25mm | 1 | 0 | 0.79 | 77659 | 98302 | Service Splice | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 5/18/2021 ✔